Gunnebo Speedstile Fl Installation Manual Review

Ensure a dedicated ground wire connects to the main chassis earth stud. Inter-Cabinet Synchronization Cable

The wings detect the resistance or sensor blockage, instantly reverse to the open position, and trigger a warning log. Disconnect or open the FACP emergency override circuit.

Standby consumption is approximately 30VA; peak consumption during leaf movement reaches up to 250VA per lane.

[ Master Cabinet ] [ Slave Cabinet ] +----------------+ +----------------+ | (A) (B) (C) | <<<<>> | (C) (B) (A) | +----------------+ Lane Width +----------------+ || || ======||==========================||====== Conduit Entry Step 1: Marking the Footprint gunnebo speedstile fl installation manual

The SpeedStile FL is a modern speed gate for high-traffic access control. Below is a specification summary based on official and secondary sources.

The subfloor must consist of solid concrete with a minimum thickness of 150 mm and a compressive strength rating of at least C20/25. Do not anchor directly into floating screed, raised access floor tiles, or lightweight materials without structural reinforcement. Electrical and Data Infrastructure

The modern corporate environment requires security solutions that are robust yet unobtrusive. The Gunnebo SpeedStile FL (Fast Lane) Ensure a dedicated ground wire connects to the

If you need help with a specific part of the setup, let me know:

: Anchor bolts require a minimum depth of 70mm into concrete with a resistance of at least 30N/mm².

: The floor must be level within +/- 5mm over the entire footprint. The subfloor must consist of solid concrete with

| Mode | Description | Use Case | | :--- | :--- | :--- | | | Flaps remain closed; passage requires valid credential. | Secure entry during business hours. | | Unlocked | Flaps remain open; acts as a free passage. | Fire evacuation or lunch breaks. | | One-Way | Entry lane unlocked, exit lane locked. | Event check-in. | | Momentary Open | Flaps open for 5 seconds after valid card, then close. | High-security anti-tailgating. |

Connect the building’s Fire Alarm Control Panel (FACP) to the dedicated emergency input terminal (normally closed contact). Opening this circuit cuts power directly to the brake or motor matrix, allowing the glass wings to instantly fail-open in the direction of egress. 5. Commissioning, Calibration, and Testing

The of your SpeedStile FL (e.g., FLs, FL EV, wide or standard lane)

Verify that the top LED pictograms display a red cross or a green arrow indicating system readiness. Sensor Calibration

Ensure the earth grounding wire is securely bonded to the central grounding stud on the chassis. Cabinet Interconnection