Obtaining the official English manual directly from the manufacturer is the most reliable way to get the exact document.
. When there is no active hot water demand, the screen displays current central heating output water temperature. 3. Adjusting Domestic Hot Water (DHW)
Being a conventional (non-condensing) boiler, it may be less energy-efficient than modern condensing models like the Baymak Premix
Before adjusting system parameters, review the factory performance limits listed in the official Lambert LX 24 Fi Technical Brochure: Specification Details 24.8 kW (21,300 Kcal/h) Efficiency Rating 93.6% Efficiency (3-Star 92/42 CEE Directive) Exchanger System Dual Heat Exchanger (Bitermik/Çift Eşanjör) Flue/Chimney Type Hermetic (Forced Fan Exhaust) Hot Water Delivery 13.7 Liters per minute ( Gas Compatibility Natural Gas or Propane (LPG) Valving System 3-Way motorized valve Control Panel & System Interface Lambert Lx 24 Fi Manual English
Its wall-mounted nature (725mm height) fits well in smaller spaces like kitchens. No Smart Features:
Intake 0.10–0.15 mm, Exhaust 0.15–0.20 mm.
Ensure that only the radiators in rooms you are using are on. Obtaining the official English manual directly from the
Connects to the radiator supply line.
Turn clockwise to increase the radiator temperature (typically 30-85°C).
The system water pressure for the heating circuit should be maintained between (with the ideal operating range around 1.2–1.5 bar) when the system is cold. Ensure that only the radiators in rooms you are using are on
The Lambert LX 24 Fi, like any boiler, can encounter issues. The display shows error codes to help identify the problem. Here are some common error codes and initial troubleshooting steps you can take before calling a service technician:
To preserve operational safety, lower fuel consumption, and protect your warranty, perform an annual maintenance checklist:
When the safety control board detects operational anomalies, it triggers a hard lock or soft fault on the digital display. Use this translated diagnostic matrix from the Baymak Service Manual to identify faults: Fault Code A01 / E01: Ignition Failure
This public link is valid for 7 days and shares a thread, including any personal information you added. This link or copies made by others cannot be deleted. If you share with third parties, their policies apply. Can’t copy the link right now. Try again later.
The boiler ignores heating requests and only ignites when a hot water tap is opened.