The official source for the German version.
To verify compliance, DIN EN 60352-2 outlines two primary testing paths:
Disclaimer: This write-up is for informational purposes. For official technical verifications, manufacturing guidelines, and legal compliance, the official purchased standard document should be consulted. din en 60352-2 pdf
One of the most critical metrics in DIN EN 60352-2 is the minimum pull-out force. This test measures the mechanical integrity of the joint. The wire must not pull out of the terminal below a specified force threshold, which scales with the wire's cross-sectional area. 4. Contact Resistance
). Engineering groups like HARTING Technology Group document these specific pull-out thresholds to ensure long-term field stability: Wire Gauge Cross-Section ( mm2m m squared Approximate AWG Equivalence Minimum Pull-Out Force Required ( 0.25 0.50 1.50 2.50 6.00 Standardized Testing and Validation Protocols The official source for the German version
The standard specifically covers solderless crimped connections . It provides a comprehensive framework to ensure that connections remain electrically stable and mechanically sound under various environmental conditions. Key Specifications:
: The crimp is cut, polished, and examined under a microscope. This ensures proper deformation, absence of voids, and complete symmetry. Environmental and Electrical Testing One of the most critical metrics in DIN
: Covers wire diameters ranging from 0.25 mm to 3.6 mm .